Fiche technique du produit - KVKVEB-6/30
Disjoncteur a courant résiduel,électronique,2P,1 mod.,car. B
B6, 30mA, 6kA, AC, E3
Code d'article:KVKVEB-6/30
(EAN: 5997374176873)
B6, 30mA, 6kA, AC, E3
Disjoncteur a courant résiduel,électronique,2P,1 mod.,car. B
Code d'article:KVKVEB-6/30 (EAN: 5997374176873)Caractéristiques techniques B6, 30mA, 6kA, AC, E3
86 pc(s) en stock
Extra discount: 5,00 %
HT
33,60526 EUR 31,92500 EUR
33,60526 EUR 31,92500 EUR
TTC
42,67868 EUR
40,54475 EUR
nombre de pôles (total):
2
nombre de pôles protégés:
1
tension assignée (Ue):
230 V
tension d`isolement assignée (Ui):
690 V
tension assignée de tenue aux chocs (Uimp):
4 kV
calibre/courant nominal assigné (In):
6 A
sensibilité / courant de défaut nominal (IΔn):
0,03 A
type de courant différentiel:
AC
classe de limitation d`énergie (I²t):
3
type de tension:
AC
fréquence:
50/60 Hz
caractéristique de déclenchement (type/courbe):
B
pôle neutre sectionné simultanément:
Oui
température ambiante en fonctionnement:
-25 -55 °C
largeur en nombre de modules:
1
montage encastré:
Oui
indice de protection (IP):
IP20
section de raccordement cable rigide:
1 -16 mm²
section de raccordement cable souple:
1 -16 mm²
Garantie:
2 année
KVKVEB-6/30 | 6 | 30 |
The combined protective switch is mainly used in electrical installations of buildings, for personal, overload and short circuit protection. It is especially suitable for electrical protection of rooms with increased safety requirements. The current transformer of the protective switch, namely the magnetic quick breaker and the bimetallic, thermal, residual current breaker are placed in the same box. It breaks the circuit of the protected device only in one pole. The device is equipped with optical display for signaling the operational state: the red color marks the “ON” state of the switch. Correct operation of the device can be controlled by pushing the “T” test button. The test should possibly be effected monthly.
Rated operating voltage:
|
220 – 240 V AC
|
Rated insulation voltage:
|
690 V AC
|
Rated impulse withstand voltage:
|
6 kV
|
Applicable shunt fuse:
|
max. 40 A gG
|
Short circuit withstand (with shunt fuse):
|
25 kA
|
Rated switching ability:
|
max. 300 A (cos = 0,65)
|
Rated short circuit breaking ability:
|
6 kA
|
Electrical life:
|
4000 switching cycles
|
Mechanical life:
|
20 000 switching cycles
|
Protection against external effects:
|
Shock and UV proof plastic housin
|
The thermal trip units are inaccessible from outside
|
|
Number of poles:
|
1
|
Protection degree:
|
IP 40
|
Mounting:
|
Clip-on 35×7,5 mm size mounting rail
|
Way of termination:
|
With female clips
|
Terminal capacity:
|
1,0 –16 mm2
|
Locking:
|
The switching arm is lead-sealable in „OFF” position
|
Ambient temperature:
|
-25…+50 °C
|
Tracon code
|
Tripping characteristics |
Rated current
|
Rated residual current |
KVKVEB-6/30
|
„B”
|
6 A
|
30 mA
|